VENT PARTS AND TERMINAL CLEARANCES:

Initial Installation

QUALIFIED INSTALLERS ONLY

VENT PARTS AND TERMINAL CLEARANCES:

Table 3: Vent part numbers.

Simpson Duravent (SD), Selkirk (SEL), and Security Chimneys (SC), must state if galvanized or black wanted, PART NUMBERS:

SD

SEL

SC

Description

SD

SEL

SC

Description

 

 

 

 

 

 

 

 

908

4DT-6

SV4L6

6” pipe length

911

 

 

11” to 14 5/8” pipe, adjustable

907

4DT-9

 

9” pipe length

 

4DT-AJ

 

4” to 10” pipe , adjustable

 

 

 

 

 

 

 

 

906

4DT-12

SV4L12

12” pipe length

 

 

SV4LA12

11⁄2” to 12” pipe , adjustable

 

 

 

 

 

 

 

 

904

4DT-24

SV4L24

24” pipe length

943

4DT-AF6

 

Flashing, 0/12 to 6/12 roof pitch

 

 

 

 

 

 

 

 

903

4DT-36

SV4L36

36” pipe length

943S

4DT-AF12

 

Flashing, 7/12 to 12/12 roof pitch

 

 

 

 

 

 

 

 

902

4DT-48

SV4L48

48” pipe length

 

 

SV4FA

Flashing, 1/12 to 7/12 roof pitch

 

 

 

 

 

 

 

 

945

4DT-EL45

SV4EBR45

45° elbow, black

 

 

SV4FB

Flashing, 8/12 to 12/12 roof pitch

 

 

 

 

 

 

 

 

990

4DT-EL90

SV4EBR90

90° elbow, black

943F

 

SV4F

Flat flashing

 

 

 

 

 

 

 

 

950

4DT-VS

SV4VS

Vinyl siding standoff/

980

4DT-VC

SV4CGV

Vertical termination

 

 

 

sheild

 

 

 

 

 

 

 

 

 

 

 

 

942

4DT-WT

SV4RSN

Wall thimble

991

4DT-HVC

 

High wind vertical termination

 

 

 

 

 

 

 

 

953

4DT-SC

SV4FC

Storm collar

984

4DT-HC

SV4CHC

Horizontal square termination

 

 

 

 

 

 

 

 

963

4DT-FS

SV4BF

Fire stop

985

4DT-HHC

 

High wind horizontal termination

 

 

 

 

 

 

 

 

988

4DT-WS/B

SV4BM

Wall strap/support/band

978

4DT-VKC

SV0FAK

Vertical termination kit

 

 

 

 

 

 

 

 

970

4DT-HKA

SV0SHK

Horizontal termination kit

971

4DT-HKB

SV0SHK2

Horizontal termination kit

 

 

 

(SD: Basic Kit, SEL: Kit A,

 

 

 

(SD: Kit A, SEL: Kit B, SC: Kit)

 

 

 

SC: Standard Kit)

 

 

 

 

 

 

 

 

 

 

 

 

The Sherwood Home Collection of fireplaces have been tested and certified for use with SIMPSON DURAVENT TYPE GS PIPE FOR GAS STOVES. SECURITY CHIMNEY’S “SECURE VENT DIRECT VENT SYSTEM” and SELKIRK “METALBESTOS MDV VENT SYSTEM” kits are available for horizontal venting. When using Simpson Duravent, it is recommended that, before installation, a bead of RTV High Temperature Silicone should be applied to each outer vent joint, and Mil-Pac to each inner joint. When planning an installation, it will be necessary to select the proper length of vent pipe for the particular requirements.

VENTING:

This fireplace has been tested and certified for use with SIMPSON DURAVENT TYPE GS PIPE FOR GAS STOVES, SECURITY CHIMNEY’S “SECURE VENT DIRECT VENT SYSTEM” and SELKIRK “METALBESTOS MDV VENT SYSTEM”

A 1 inch (2.5 cm) clearance to combustibles must be maintained around any vertical vent pipe. Around a horizontal vent pipe, the clearance to combustibles should be 2 inches (5 cm) above and 11⁄2 inches (4 cm) on the sides and bottom. When combustible materials are directly above a 90° elbow, 3 inches (7.6 cm) of clearance are necessary. A 10 inches (25 cm) x 10 inches (25 cm) frame will assure the proper support and spacing for the vent pipe as it passes through the wall. Installations in Canada require that a wall thimble be used for passing through walls and ceilings, see Figure 21. All sealing and vapour barriers must comply with local building codes.