Operating Instructions

For Your Safety, Read Safety Precautions And

Lighting Instructions Before Operating

BURNER LIGHTING:

A)Make sure the pilot is lit.

B)Turn gas control knob COUNTER CLOCKWISE to ON.

C)Flip the burner switch to ON.

D)Turn HI/LO knob to the desired flame height.

E) Turn on all electrical power to the unit.

NOTE: Check that all burner holes are lit.

TO TURN GAS FIREPLACE OFF:

 

���

 

 

Flip switch to OFF to turn off burners only.

 

�������

 

 

If the fireplace is to be turned off for the season,

����� �������

������

����

 

or for servicing, turn the gas shut off valve to

 

 

OFF. DO NOT FORCE IT. If the unit is going to

 

 

be serviced, turn off the electrical power to the

 

 

unit as well.

Figure 5. Control Panel

NOTE: When the unit is turned on for the first time, it should be turned onto high, with the fan OFF, for the first two to four hours. This will cure the paint, logs, gasket material, and other products used in the manufacturing process. It is advised that a door or window be opened as the unit will start to smoke, which can irritate some people. After the unit has gone through the first burn, turn the unit OFF, including the pilot, and let the unit get completely cold. Then remove the glass and clean it with a good gas fireplace glass cleaner, available at your local Enviro dealer. See “MAINTENANCE AND SERVICE; GLASS

DOOR REMOVAL” and “MAINTENANCE AND SERVICE; CLEANING THE GLASS.”

BLOWER SPEED (OPTIONAL):

The blower will come on only when the fireplace is up to temperature (approximately 20 minutes). The speed of the fan can be changed by turning the fan control knob. To turn the blower off, turn the knob COUNTER CLOCKWISE until it “clicks” off (Figure 6).

It is advisable not to operate the blower below 1/3 speed as it puts a strain on the windings of the blower and running the blower at lower speeds could also cause premature fan failure.

NORMAL SOUNDS DURING OPERATION:

��

���

��

Figure 6. Fan Control

 

Table 1: Normal Sounds

 

 

Component

Sound & Reason

 

 

DV36 & Fascia

Creaking when heating up or cooling down.

 

 

Burner

Light pop or poof when turned off; this is more common with LP units.

 

 

Temperature Sensor

Clinking when it senses to turn the blower on or off.

 

 

Pilot Flame

Quiet whisper while the pilot flame in on.

 

 

Blower / Fan

Air movement that increase and decreases with the speed of the blower. The

 

blower is pushing the heat from the fireplace into the room.

 

 

Gas Control Valve

Dull click when turning on or off, this is the valve opening and closing.

 

 

8

Page 8
Image 8
Enviro DV36 owner manual To Turn GAS Fireplace OFF, Component Sound & Reason