Operating Instructions
For Your Safety, Read Safety Precautions And
Lighting Instructions Before Operating
BURNER LIGHTING:
A)Make sure the pilot is lit.
B)Turn gas control knob COUNTER CLOCKWISE to ON.
C)Flip the burner switch to ON.
D)Turn HI/LO knob to the desired flame height.
E) Turn on all electrical power to the unit.
NOTE: Check that all burner holes are lit.
TO TURN GAS FIREPLACE OFF: |
| ��� | |
|
| ||
Flip switch to OFF to turn off burners only. |
| ������� | |
|
| ||
If the fireplace is to be turned off for the season, | ����� ������� | ������ | |
���� | |||
| |||
or for servicing, turn the gas shut off valve to |
|
| |
OFF. DO NOT FORCE IT. If the unit is going to |
|
| |
be serviced, turn off the electrical power to the |
|
| |
unit as well. | Figure 5. Control Panel |
NOTE: When the unit is turned on for the first time, it should be turned onto high, with the fan OFF, for the first two to four hours. This will cure the paint, logs, gasket material, and other products used in the manufacturing process. It is advised that a door or window be opened as the unit will start to smoke, which can irritate some people. After the unit has gone through the first burn, turn the unit OFF, including the pilot, and let the unit get completely cold. Then remove the glass and clean it with a good gas fireplace glass cleaner, available at your local Enviro dealer. See “MAINTENANCE AND SERVICE; GLASS
DOOR REMOVAL” and “MAINTENANCE AND SERVICE; CLEANING THE GLASS.”
BLOWER SPEED (OPTIONAL):
The blower will come on only when the fireplace is up to temperature (approximately 20 minutes). The speed of the fan can be changed by turning the fan control knob. To turn the blower off, turn the knob COUNTER CLOCKWISE until it “clicks” off (Figure 6).
It is advisable not to operate the blower below 1/3 speed as it puts a strain on the windings of the blower and running the blower at lower speeds could also cause premature fan failure.
NORMAL SOUNDS DURING OPERATION:
��
���
��
Figure 6. Fan Control
| Table 1: Normal Sounds |
|
|
Component | Sound & Reason |
|
|
DV36 & Fascia | Creaking when heating up or cooling down. |
|
|
Burner | Light pop or poof when turned off; this is more common with LP units. |
|
|
Temperature Sensor | Clinking when it senses to turn the blower on or off. |
|
|
Pilot Flame | Quiet whisper while the pilot flame in on. |
|
|
Blower / Fan | Air movement that increase and decreases with the speed of the blower. The |
| blower is pushing the heat from the fireplace into the room. |
|
|
Gas Control Valve | Dull click when turning on or off, this is the valve opening and closing. |
|
|
8