Enviro DV36 owner manual Initial Installation, Qualified Installers Only

Models: DV36

1 40
Download 40 pages 5.01 Kb
Page 22
Image 22
relative to the length of vent pipe. The

Initial Installation

QUALIFIED INSTALLERS ONLY

VENT CONFIGURATIONS AND RESTRICTOR SETTINGS:

Figures 23 shows the range of venting options, it shows possible vent configurations if the unit is top vented, for vertical and horizontal terminations, any layout that remains within the shaded area is acceptable. Having the fewest number of elbows is ideal, as they tend to disrupt air movement. Using 45˚ elbows is preferable to using 90˚ elbows. Also, a shorter vent system will perform better than a longer one.

The vent restrictor controls the amount of air moving through the vent pipe. Longer vertical vent lengths necessitate greater restriction; position 1 is open and position 5 is maximum restriction. Figure 31 shows the vent restrictor position required,

NOTE: The total length of the vent pipes can

relative to the length of vent pipe. The

not exceed 32 feet (15.12 m). Any combination

vent restrictor is located in the center of

of rise and run can be used as long as it lays

the fireplace, above the glass. Figure 32

within the shaded area (a total of three (3) 90°

shows the vent restrictor dial and the holes

elbows or six (6) 45° elbows can be used).

In addition to what is shown, if a 90°

that indicate the different levels. To avoid

elbow is used in the horizontal plane,

injury, it is best to make this adjustment

3 feet (91.4 cm) must be subtracted

when the fireplace is cool or use welder’s

from the allowable horizontal run

(for each 45° elbow, 11⁄2 feet

gloves or oven mitts.

must be subtracted from the

Note: 0,0 in Figure 31 represents a 90˚

allowable horizontal run).

 

bend directly off the outlet of the unit, 413⁄4

 

inches (106 cm) from floor, in all horizontal

 

instances except when using Selkirk and

 

having less than a 4 feet (1.22 m) rise

 

and 8 feet (2.44 m) horizontal offset. In

 

this case, a 1 foot (30.5 cm) rise must be

 

added below the 90˚ bend.

 

Note for rear vented: At 293⁄8 inches (75

 

cm) up, the maximum horizontal rear exit

 

vent length is 17 inches (43 cm) with a 45°

 

elbow (see Figure 17).

Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background

Figure 31. Possible Vent Configurations for Top Vented; Vertical Figure 32. Possible Vent Restrictor Positions. and Horizontal Terminations.

22

Page 22
Image 22
Enviro DV36 owner manual Initial Installation, Qualified Installers Only, relative to the length of vent pipe. The