Enviro owner manual Codes And Approvals, VENTED GAS FIREPLACE HEATER EG40 BV NG/LPG

Models: EG40 BV

1 23
Download 23 pages 16.42 Kb
Page 4
Image 4
Codes And Approvals

Codes And Approvals

BV: This Vented appliance draws all of its combustion air from the dwelling and must be vented using listed B or L vent. May also be vented through a conventional chimney using a chimney liner kit.

This appliance has been tested and approved for installations from 0 feet to 2000 feet (610 m) above sea level.

In the USA: The appliance may be installed at higher altitudes. Please refer to your American Gas Association guidelines which state: the sea level rated input of Gas Designed Appliances installed at elevations above 2000 feet (610 m) is to be reduced 4% for each 1000 feet (305 m) above sea level. Refer also to local authorities or codes which have jurisdiction in your area regarding the de-rate guidelines.

In Canada: When the appliance is installed at elevations above 4500 feet (1372 m), the certified high altitude rating shall be reduced at the rate of 4% for each additional 1000 feet (305 m).

This appliance has been tested by INTERTEK (Warnock Hersey) and found to comply with the established VENTED GAS FIREPLACE HEATER standards in CANADA and the USA as follows:

VENTED GAS FIREPLACE HEATER (EG40 BV NG/LPG)

TESTED TO: ANSI Z21.88a-2003/CSA 2.33a-2003 VENTED GAS FIREPLACE HEATERS

CAN/CGA 2.17-M91 GAS FIRED APPLIANCES FOR HIGH ALTITUDES

CSA P.4.1-02 TESTING METHOD FOR MEASURING ANNUAL FIREPLACE EFFICIENCY

This ENVIRO EG40 BV Fireplace:

Has been certified for use with either natural or propane gases. (See rating label.)

Is not for use with solid fuels.

Is approved for bedroom or bed sitting room. (IN CANADA: must be installed with a listed wall

thermostat. IN USA: see current ANSI Z223.1 for installation instructions.)

Must be installed in accordance with local codes. If none exist, use current

installation code CAN/CGA B149 in Canada or ANSI Z223.1/NFPA 54 in the USA.

• Must be properly connected to an approved venting system and not connected to a chimney flue serving a separate solid-fuel burning appliance.

Are approved for installation on combustible materials (i.e. Wood, carpet or linoleum).

Is not approved for closet or recessed installations.

IMPORTANT NOTICE (Regarding first fire up): When the unit is turned on for the first time, it should be turned onto high without the fan on for the first 4 hours. This will cure the paint, logs, gasket material and other products used in the manufacturing process. It is advisable to open a window or door, as the unit will start to smoke and can irritate some people. After the unit has gone through the first burn turn the unit off including the pilot, let the unit get cold then remove the glass door and clean it with a good gas fireplace glass cleaner, available at your local ENVIRO dealer.

4

Page 4
Image 4
Enviro owner manual Codes And Approvals, VENTED GAS FIREPLACE HEATER EG40 BV NG/LPG, This ENVIRO EG40 BV Fireplace