Enviro EG40 BV owner manual Initial Installation, Qualified Installers Only, Number of 90 elbows

Models: EG40 BV

1 23
Download 23 pages 16.42 Kb
Page 8
Image 8
Number of 90° elbows

Initial Installation

QUALIFIED INSTALLERS ONLY

STRAIGHT VERTICAL INSTALLATION:

This basic venting configuration shown are rough guidelines only. Follow national and local codes for other installation options.

For the best venting performance, we recommend a total vent height in the range of 10 feet (3.0 m) to 30 feet (9.1 m). The total horizontal length depends on the number of elbows used; a 90° elbow accounts for 5 feet (1.5 m) of the horizontal run.

The venting should never slope down, a minimum 1⁄4 inch (0.6 cm) rise is needed for every 2 feet (61 cm) of horizontal is recommended.

If practical, it is best to locate the appliance to permit the use of shorter horizontals and fewer elbows.

Table 1. 90° elbows allowed verses the

horizontal length.

Number of 90° elbows

Maximum total horizontal

 

length allowed

 

 

2

20 feet (6.1 m)

 

 

3

13 feet (4.0 m)

 

 

4

6 feet (1.8 m)

 

 

5

0 feet (0 m)

 

 

Note: Using two (2) 45° elbows is equivalent to using one (1) 90° elbow.

The venting rise should be a minimum of 1 foot (0.31 m) from the top of the unit before any horizontal run are used.

Figure 5: Straight vertical installation.