4.1 ADJUSTMENT OVERVIEW
4.1.1 Required Adjustments
This sectiondescribe swhat adjustmentsare required after anypart is removed or replaced. Thefollowing
table showsthe relationship betweenthe repaired itemand the adjustment.
Table 4-1 Required Adjustments
Repaired Item \ Adjustment Platen
Gap Bi-d Print
Alignment Factory
Settings TPE Level
Reset
Printer Mechanism Replacement —- ( ❇1) ❍(❇2) —- ❍
Main Board Replacement —- ❍❍—-
EEPROM Replacement —- ❍❍—-
PW Sensor Assembly Replacement —- —- —- ❍
Platen Assembly Replacement or Removal ❍—- —- —-
CR Motor Assembly Replacement or Removal —- ❍—- —-
Right Frame AssemblyReplacement or
Removal ❍❍—- —-
Right Frame Disassembly —- ❍—- —-
Left Frame Replacement orRemoval ❍❍—- —-
RD Assembly Replacement or Removal ❍❍—- —-
CR Assembly Replacement or Removal ❍❍—- —-
(❇1) : —-means adjustmentis not required.
(❇2) : ❍means adjustment is required.
When any part is replaced or reassembled, use the Check Program included on the Settings
Diskette, and check the performance and settings of various check patterns.
4.1.2 Required Adjustment Tools
Thefollowing table showsthe tools required for each adjustment.
Table 4-2 Required Adjustment Tools
Adjustment Required Tool Page
Platen Gap Thickness Gauge (B776702201) 4-2
Bi-d Print Alignment Settings Diskette ( ❇1) or RemoteUtility or Panel Operation 4-4
Factory Settings (❇2) Settings Diskette 4-7
TPE Level Reset Settings Diskette 4-8
❇1: TheSettings Diskette contains 3 settingsprograms: the bidirectional adjustment program,
factorysettin gsprogram, and TPE (toppaper end) level rewrite. Thediskette also includes 4
check programs: continuous form paper,A3 cut sheets, A4 cutsheets, and envelopes.
❇2: This factory settings programincludes several factory settingitems. Using this program sets
theprinter to thedestination factory settings.
FX-2170 Service Manual Adjustment
Rev. A 4-1