Physical | Operational ambient | 0 to +50 °C |
|
|
| ||
environmental | temperature |
|
|
|
|
| |
conditions |
|
|
|
|
| ||
Storage ambient |
|
| |||||
| temperature |
|
|
|
|
| |
| Operational ambient | 85 % RH or less |
|
| |||
| humidity | (Without dew condensation, max. | |||||
| Operational altitude | 2000 m or less above sea level (Transport condition: 70 kPa or more) | |||||
|
|
|
|
|
| ||
| Operational atmosphere | No corrosive gas, no excessive dust, no conductive dust contamination, and | |||||
|
|
| not stained with organic solvents. |
| |||
| Pollution degree | 2 | (Note1) |
|
| ||
|
|
|
|
|
| ||
Mechanical | Vibration resistance |
| |||||
working |
|
| X, Y, Z: 3 directions for one hour |
| |||
conditions | Shock resistance | Peak acceleration: 147 m/s2, X, Y, Z: 3 directions three times each | |||||
Electrical | Noise resistance | Rising time: 1 ns, pulse width: 1 µs, Noise voltage: 1.5 | |||||
working |
|
| (Measured by using a noise simulator.) |
| |||
conditions |
|
|
|
|
| ||
Static electricity | Contact: ±4 kV, air: ±8 kV |
|
| ||||
| discharge resistance |
|
|
|
|
| |
Power supply | Rated input voltage | 24V DC |
| (Note2) |
|
| |
| Rated voltage (tolerance) | 24V DC ±10% |
|
| |||
|
|
|
|
|
| ||
| Permissible momentary | 1 ms or less |
|
| |||
| power failure |
|
|
|
|
| |
| power supply consumption | 42 W or less | 37 W or less | 35 W or less | |||
| (Max. rated) |
|
|
|
|
| |
| Rush current | 170 A or less |
|
| |||
|
|
|
|
|
|
|
|
| Input terminal block |
|
|
|
|
| |
|
|
|
|
|
| ||
|
| Display unit | Terminal block screw: M3.5 | - (Connection to the | |||
|
|
|
|
|
| controller unit) | |
|
|
| Tightening | torque: 0.8 N·m | |||
|
|
|
|
|
| ||
|
| Controller unit | Terminal block screw: M3 |
|
| ||
|
|
|
|
|
|
| |
|
|
| Tightening | torque: 0.5 to 0.6 N·m |
| ||
|
|
|
|
|
| ||
| Dielectric strength | 500 V AC 1 minute (Between external terminals and frame ground) | |||||
|
|
|
|
|
| ||
Isolation resistance | 500 V DC, 5 MΩ or more |
|
| ||||
|
|
|
|
|
| ||
Dimensions W x H x D (mm) | 326.4 x 259.6 x 99.0 | 303.8 x 231.0 x 99.0 | 233.0 x 178.0 x 96.0 | ||||
Mass |
|
| Approx. 3.5 kg | Approx. 3.1 kg | Approx. 2.1 kg |
Note 1) Pollution degree 2: This pollution does not conduct usually, but under certain circumstances temporary conductivity occurs due to condensation.
Note 2) Use 24V DC power supply which comply to UL standard Class2 insulation.
• Installation specifications
Item | Specifications | |
Grounding | Less than 100Ω , FG/SG separated | |
|
|
|
Protection structure | Front panel (Note 1) | Compliant with IP65 (When using waterproof gasket) (Note 2) |
|
|
|
Cooling system | Cooling naturally | |
|
|
|
Structure | Inserted in a mounting panel | |
Appropriate mounting panel thickness | 1.5 to 5 mm |
Note: 1) Protection structure for the front when the @E.Terminal is mounted on the mounting panel.
Note: 2) It is recommended to use the mounting panel whose thickness (steel, stainless) is 3.0 mm or more to keep the unit compliant with IP65. The strength differs depending on the material of the mounting panel. Check the environment where the @E.Terminal is used.