Warning | Electric shock hazard. |
Shut the power off before wiring the power supply cable. |
(1) Power supply cable wiring
Power supply terminal blocks of the display unit and the controller unit are connected with each other with a cable by default. Use one power supply terminal block to connect the power supply cable.
•For
Connect the power supply cable to the power supply terminal block of the display unit.
| CN7 |
| CN5 |
ONL | |
ERR | |
UROM | |
IN | RUN |
ALM | |
| BAT |
•For
Connect the power supply cable to the power supply terminal block of the controller unit.
CF
CN7
ONL | |
ERR | |
IN | UROM |
ALM | |
| RUN |
| BAT |
4:RUN |
2:TERM |
1:STOP |
CPU |
No. |
OUT |
+ |
CN5
OUT
4:RUN
CPU
No.
24V DC |
|
|
|
|
|
- |
|
|
|
|
|
FG |
|
|
|
| CF |
| USER ROM CARD | USB |
|
| |
|
| LOADER |
|
|
|
MJ1 | MJ2 | CN1 | LAN |
+
24V DC
- 24VDC
FG FG
USER ROM CARD | USB | LAN | |
| CN1 |
LOADER
MJ1 MJ2
|
| Power | + | |
|
| 24V DC | ||
24V DC | supply | |||
- | ||||
| ||||
+ | - | Grounding |
| |
| FG | FG | ||
|
|
|
Power supply
Grounding
• Attaching noise filter
Attach accompanying noise filter to the power supply cable between the DC power supply and the power supply terminal block.
Keep the distance between the DC power supply and the power supply module as short as possible, and the cable must be twisted densely.
|
| @E.terminal side |
DC power |
| + |
Noise filter | 24V DC | |
supply | (accessory) | - |
|
|
FG
Do not bundle up and do not close.
*Noise filter is not required for controller unit hardware version “03” or later. Noise filter is not attached as accessory with above version.