4.1.3 Platen Gap Adjustment
Following the removal of the carriage guide shaft or adjust lever, or if printing is abnormal, the gap
between the platen and the print head should be adjusted.
1. Remove the printer mechanism (See section 3.2.4),
2.
Remove the
printhead.
Using tweezers, remove the ribbon mask. Remove the maskby pulling
it slightly forward, then lifting.
Figure 4-3. Removal of Ribbon Mask
3. Reinstall the
printhead.
4. Set the release lever to the friction position.
5. Set the parallel adjust lever to the center position.
6. Manually move he carriage to column 126.
7. Lightly loosen the
HMO(M4)
nut securing the head adjust lever.
m
Figure 4-4. Head Adjust Lever B