Troubleshooting
LX-105O+ Service Manual
Table 5-5. The Printer does Not Operate at All
Cause Step
The
TA-a
filter unit maybe
~
dead.
I
The
TAMA
board maybe
bead.
4
Checkpoint
Finding
Is
connector
CN9
on the
TAMA
board disconnected?
Yes
Is the fuse F1 on the
TA-a
filter unit blown?
Yes
With the power on, are there
output of 26
VAC
between
two red wires and 12
VAC
No
between two blue wire for
CN1
on the
TA-a
filter unit.
Solution
Connect
CN9
on
TAMA
board
Replace the fuse
F1 .
Replace the
TA-a
filter unit.
Replace the
TAMA
boafd
Table 5-6. The LEDs do Not Operate at All
Cause Step
Checkpoint
Finding
Solution
Connector
CN3
on the
TAMA
,Is connector
CN3
on the
Yes
Connect
CN3
on
board may be disconnected. TAMA
board disconnected? the
TAMA
board.
Control panel may be dead. 2
Replace the
control panel.
The
TAMA
board maybe
3
Replace the
dead.
TAMA
board.
Table 5-7. The Buttons do Not Operate at AllCause Step
Checkpoint
Finding
Solution
Connector
CN3
on the
TAMA
,Is connector
CN3
on the
board may be disconnected. TAMA
board disconnected?
Yes
Connect
CN3
on
the
TAMA
board.
Control panel may be dead.
2
Replace the
control panel.
The
TAMA
board maybe
dead. 3Replace the
— —
TAMA
board.
54
Rev.
A