Troubleshooting
LX-1050+ Service Manual
5.2 SELF-DIAGNOSTIC FUNCTION
This section describes the
selfdiagnostic
function, in which the controller automatically checks the
operating conditions of each component.
If
any abnormality is detected, the printer displays an
error message by beep sound. Table
5-3
lists
the messages that tell you
if
service maintenance is
required.

Table 5-3. Error Codes

Error
I
Buzzer
Carriaae
trouble
I
Bee~s
6 times,
pausing
after 3rd
beep
Paper out
Beeps 20 times, pausing briefly after 4 beeps
Abnormal voltage Beeps 8 times, pausing after every beep
Incorrect SRAM
Beeps 8 times, pausing briefly after 2 beeps
I
Incorrect RAM inside CPU
I
Beeps indefinitely until power OFF
5-2
Rev. A