Fig. 10 Setting DIP Swtiches
Table 1 Functions and Conditions of DIP Switch B
Pin No. |
| Function | Off |
| On |
| |
B1 |
|
|
| See |
|
| O N |
B2 |
| Baud Rate |
|
|
| OFF | |
B3 |
|
| Table 3 |
|
| O N | |
|
|
|
|
| |||
|
|
|
|
|
| ||
B 4 |
|
|
|
|
|
| OFF |
Table 2 Functions and Conditions of DIP Switch A | |||||||
|
|
|
|
|
|
| |
Pin No . |
| F u n c t i o n | Off |
| On | ||
|
|
|
|
|
|
| |
A 1 |
| Transmission | ASCII |
| BAUDOT | OFF | |
|
| C o d e |
|
|
|
|
|
A 2 |
| I n A S C I I | m o d e | See Table 4 | ON | ||
|
| sets Word | Struc- |
|
|
| ON |
A 3 |
|
|
|
| |||
| ture |
|
|
|
|
| |
|
|
|
|
|
|
| |
A 4 |
| In Baudot | mode | See Table | 5 | ON | |
| s e t s C o d e T a b l e |
|
|
|
| ||
|
|
|
|
|
| ||
|
|
|
|
|
|
| |
A 5 |
| Line Spacing | 1 / 3 " |
| 1/6" | ON | |
A 6 |
| AUTO FEED XT | Invalid |
| Valid | OFF | |
A 7 |
| Not used |
|
|
|
| OFF |
|
|
|
|
|
|
| OFF |
A 8 |
|
|
|
|
|
|
3. At this time, refer to Table 3 and set the baud rate to your requirements.