3.3. Setting of jumpers

Your application may require the removal or installation of jumpers of the SMCT Board. Before continuing, consult Table 6 which outlines the function and factory-set condition of each jumper.

In order to access the SMCT Board it is necessary to remove the SMDP Board. This is accomplished by:

1.Disconnecting the Mechanism Cable and the AC cable.

2.Removing the six (6) screws on the SMDP Board and the two (2) screws located in the heat sink on the right side of the board.

3.Lifting the Board from the rear center, in the connector area, to avoid damage. NOTE:

Any changes in this area should be performed by an experienced technician.

 

Table 6

Function and Conditions of Jumpers

 

 

 

 

 

 

 

 

 

 

 

 

J u m p e r

 

 

 

 

 

Function

 

 

Factory-set

J1

Not used

 

 

 

 

 

 

 

OFF

J2

ON

 

RS-232C

OFF

 

Current Loop

Note

1

ON

J 3

OFF

 

Level

 

O N

 

Level

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

J 4

Both

 

ON

=

Polar

 

 

 

 

 

OFF

J5

Both

OFF

=

Neutral

 

 

 

 

 

OFF

J6

Not used

 

 

 

 

 

 

 

OFF

J 7

Not used

 

 

 

 

 

 

 

OFF

J8

Current Loop (USA Version)

 

 

 

ON

J 9

Both are ON when not

 

 

 

ON

J10

using RTS and CTS

 

 

 

 

 

ON

J11

ON when using CTS

 

 

 

 

 

OFF

J12

ON when using RTS

 

 

 

 

 

OFF

J13

80 mA Current Loop

 

 

 

 

 

OFF

J14

60 mA Current Loop

 

 

 

Note 2

OFF

J15

40 mA Current Loop

 

 

 

OFF

 

 

 

 

 

 

 

 

 

 

OFF

J16

20 mA Current Loop

 

 

 

 

 

 

 

 

 

 

 

Note 1: Select either J2 or J3. Do not connect both.

Note 2: Select 1 only. Do not connect 2 or more.

- 1 2 -