4.Now using Table 2, select your transmission code: ASCII or Baudot.

A. If ASCII is selected, refer to Table 4 for word length setting and parity control. B. If Baudot is selected, refer to Table 5 for selection of correct Baudot code.

5.Set Line Spacing to desired position.

6.Set Auto Feed if required. This is necessary if the host system does not transmit line feed control code.

Details of the coding structures are contained in Appendix A for ASCII and Appendix B for Baudot.

Table 3 Baud Rate Selection

 

 

 

 

Note: 1 = ON

 

Table 4 ASCII Code Table Selection

 

 

 

 

 

 

 

 

Pin No.Functionoff

On

Factory-set

 

A2

Data Length

8 bit7 bit

ON

 

A3

Parity Check

Enable

Disable

ON

 

A4

Parity

Even

Odd

ON

 

Table 5 BAUDOT Code Table Selection
SW A2SW A3SW A4CODE TABLE

ON

ON

ON

CCITT #2

OFF

OFF

ON

CCllT #2 AMERICAN

ON

OFF

ON

WU/TELEX

- 1 1 -