59
Projector Care
3Use the [l][r] buttons to select “Yes,” then press the [e] button.
The lamp operating time will be reset.

Replacing the air filter

Replacing the air filter can also be performed when the projector is mounted
to a ceiling.
1Turn off the projector power, wait for the cool-down period to
end, then disconnect the power cable.
Cool-down takes about 20 seconds.
2Push in the tab on the air filter cover and lift up the air filter cover
to remove it.
3Replace the air filter with a new one.
Take out the old air filter and install the new one. Please ensure there
are no gaps between the air filter and the plastic grill.
4Replace the air filter cover.
First insert the tabs, and then press down on the opposite side until it
clicks into place.
pDispose of used air filters properly in accordance with your local
regulations.