Pilot and Bypass Screws Conversion
1.Remove control knobs and set aside.
2.Remove upper grates.
3.Lift the cooktop by both front corners until the side support rods snap into position.
4.Open oven door.
5.Locate the two top fasteners and two bottom fasteners and remove them using a Phillips head screwdriver.
A
B
A. Top fasteners
B. Bottom fasteners
6.Set the front panel aside and locate the oven thermostat.
A
A. Oven thermostat
7.Locate the Natural gas bypass screw in the bag containing literature included with the range. One LP gas bypass screw is stamped “76.”
8.Remove the LP gas bypass screw with a
9.Install the natrual gas bypass screw with a
A
B
A. Pilot screw
B. bypass screw
10.Locate the Natural gas pilot screw in the bag containing literature included with the range. One Natural gas pilot screw is stamped “94.”
11.Remove LP gas pilot screw with a
12.Install the Natural gas pilot screw with a
13.Replace the front panel and screw bottom and top fasteners in place.
14.Replace the control knobs. Push back on the side support rods and slowly lower the cooktop until it snaps into position. Close the oven door.
Complete Conversion
1.Refer to the “Make Gas Connection” section for properly connecting the range to the gas supply.
2.Turn the manual shutoff valve in the gas supply line to the open position.
3.Refer to the “Check Operation” section for proper burner ingnition, operation and burner flame adjustments.
IMPORTANT: You may have to adjust the “LO” setting for each cooktop burner.
Checking for proper cooktop and oven burner flames is very important. The small inner cone should have a very distinct blue flame ¼" to ½" (0.64 cm to 1.3 cm) long. The outer cone is not as distinct as the inner cone. Natural gas flames do not have yellow tips.
4.Close the broiler door and turn the knob to “OFF.”
5.Refer to the “Complete Installation” section to complete this procedure.
14