Typical flexible connection
1.Use a combination wrench and pliers to attach the flexible connector to the adapters. Check that connector is not kinked.
A
B
D
C
Level Range
1.Place rack in oven.
2.Place level on rack and check levelness of range, first side to side; then front to back.
| E | F |
|
| G |
| H |
|
A. Pressure regulator | E. Adapter |
|
connection fitting | F. Use | |
B. Use | G. Manual shutoff valve | |
C. Adapter | H. ½" or ¾" gas pipe | |
D. Flexible connector |
|
|
Complete Connection
1.Open the manual shutoff valve in the gas supply line. The valve is open when the handle is parallel to the gas pipe.
A
B
A. Closed valve
B. Open valve
2.Test all connections by brushing on an approved noncorrosive
3.Push back on side support rods and slowly lower the cooktop until it snaps into place.
4.Place burners, burner caps and grates on the cooktop.
Verify Anti-Tip Bracket Location
1.Make sure the
■Look for the
■Slide the range back so the rear range foot is under the anti- tip bracket.
2.If installing the range in a mobile home, you must secure the range to the floor. Any method of securing the range is adequate as long as it conforms to the standards in the “Location Requirements” section.
3.Continue installing your range using the follwing installation instructions.
3.If range is not level, pull range forward until rear leveling leg is removed from the
4.Push range back into position.
5.Check that rear leveling leg is engaged in
Check Operation
To Light Standing Pilot Lights:
Before using the range, the standing pilots must be lit. They will stay lit after turning off the burners.
1.Make sure all controls are off and the oven and cooktop are cool.
2.Remove surface grates from the cooktop.
3.Lift the cooktop by both front corners until the side support rods snap into position.
A
A. Side support rods
4.Using a match, light both burner pilot lights.
5.The surface pilot flames should be 0.4" to 0.6" (1.0 to 1.5 cm) high.
A
A. 0.4" - 0.6" (1.0 - 1.5 cm)
8