Flow Meter FC01-LQ
Resistive load |
|
|
|
Max. admissible switching capacity: | 50 W |
|
|
Max. admissible switching current: | 1 A |
|
|
Max. admissible continuous current: | 1 A |
|
|
Max. admissible switching voltage: | 50 V |
|
|
Contact life at 1 A: | 3 x 105 cycles |
|
|
Inductive load - with safety circuit - AC voltage |
|
| |
Max. admissible switching capacity: | 125 VA |
|
|
Max. admissible switching current: | 1.25 A |
|
|
Max. admissible continuous current: | 1.25 A |
|
|
Max. admissible switching voltage: | 100 V |
|
|
Contact life cos = 0.5: | 2.4 x 105 cycles |
|
|
Insulation voltage: | signal contact - central electronic unit DC 500 V | ||
| signal contact - signal contact DC 500 V |
| |
8.4.2 Transistor outputs (DC) |
|
|
|
Pin selection: | Signal name | Pin XAH | Polarity |
| / ERROR emitter | 1 | - |
| / ERROR collector | 2 | + |
| / BUSY / PULSE emitter | 3 | - |
| / BUSY / PULSE collector | 4 | + |
| Limit Switch 2 emitter | 5 | - |
| Limit Switch 2 collector | 6 | + |
| Limit Switch 1 emitter | 7 | - |
| Limit Switch 1 collector | 8 | + |
Voltage level |
|
|
|
Low level - active: | Uce < 0.8 V at IC < 10 mA |
|
|
| Uce < 1 V at IC < 100 mA |
|
|
High level - passive: | Uce < 48 V |
|
|
| Uce max = 60 V |
|
|
| max. leakage current ≤ 25 µA |
|
|
Reverse polarity protection: | yes |
|
|
Short circuit protection: | yes |
|
|
Technical data | 51 |