Thermal Cut-Off

Thermal Cut-Off

This vacuum cleaner has a special thermostat that protects the vacuum in case of motor overheating. If the vacuum suddenly shuts off, push the power switch to off (O) and unplug the vacuum. Check the vacuum for a possible source of overheating such as a full dust cup, blocked hose or clogged filter. If these conditions are found, fix them and wait at least 30 minutes before attempting to use the vacuum. After the 30 minute period, plug the vacuum back in and turn on the switch. If the vacuum still does not work, take it to a Eureka authorized service center for repair or call 1-800-282-2886.

Problem Solving

Problem Solving!Problem Make sure vacuum is turned off and power cord is unplugged.

Problem

Cause

Solution

 

 

 

Motor will not start.

Power plug

• Push plug securely into outlet.

 

 

• Try another outlet.

 

 

• Check circuit breaker.

 

 

 

 

On / Off switch

• Turn On / Off switch to on ( I ).

 

Thermal cut-off

• See above.

 

 

 

Vacuum does not

Dust cup and filter

• Empty dust cup, clean and/or change filter.

clean carpet.

 

• Clean or replace filters regularly to maintain suction. Page 2

 

 

• If picking up fine dust, the dust cup may not look full, but a

 

 

fine substance tends to reduce suction when it blocks air

 

 

flow through the filter and screen. Refer to page 2 for filter

 

 

maintenance. Make sure filter, screen and dust cup are

 

 

installed properly.

 

 

 

 

Belt

• Replace a worn, cut or out-of-shape belt. Page 4

 

 

 

 

Hose

• Remove any clogs from the hose that restrict the

 

 

airflow. Page 5

 

 

 

 

Carpet height setting

• For carpet cleaning, turn height adjustment knob to

 

 

another position.

 

 

 

No suction at the

Dust cup and filter

• Empty dust cup, clean and/or change filter.

end of hose.

 

• Clean or replace filters regularly to maintain suction. Page 2

 

 

• If picking up fine dust, the dust cup may not look full, but a

 

 

fine substance tends to reduce suction when it blocks air

 

 

flow through the filter and screen. Refer to page 2 for filter

 

 

maintenance. Make sure filter, screen and dust cup are

 

 

installed properly.

 

Filter screen

• (Located inside dust cup). Check & clean debris to

 

 

maintain full air flow. Page 2

 

Hose

• Remove any clogs from the hose that restrict the

 

 

air flow. Page 5

 

 

 

Vacuum is hard

Vacuum height setting

• Adjust knob to a higher position.

to push.

 

 

Belt

• Replace a worn, cut or out of shape belt. Page 4

 

 

 

 

Burning smell; brush

Belt

• Check brush roll for debris. Page 4

roll will not turn.

 

• Replace broken or out of shape belt. Page 4

 

 

 

 

 