PROBLEM SOLVING

PROBLEM SOLVING

This appliance was inspected thoroughly and was in good operating condition when it was shipped from the factory. If a minor problem occurs, it usually can be solved quite easily when the cause is found. Therefore, this checklist is provided for your convenience.

PRECAUTIONARY MEASURES

Important: If the suction opening in the unit, the hose or the extension tube become blocked, switch off the vacuum cleaner and remove the blocking substance before you start the unit again.

PROBLEM

 

POSSIBLE CAUSE

 

POSSIBLE SOLUTION

 

 

 

 

 

 

1.

Not properly plugged into wall

1.

Plug in firmly.

 

 

outlet.

2.

Check fuse or breaker.

Cleaner Won’t

2.

No electricity in wall outlet.

3.

Push on/off switch to on

Run

3.

On/Off switch not turned on.

4.

Reset motor thermostat.

 

4.

Motor thermostat tripped.

5.

Reset circuit breaker or

 

5.

Blown fuse/tripped breaker.

 

replace fuse.

 

 

 

 

 

 

1.

Full or clogged dust cup.

1.

Clean dust cup (container).

 

2.

Adjust setting.

 

2.

Wrong pile height setting.

 

3.

Remove obstruction.

 

3.

Clogged nozzle.

 

4.

Remove power head cover

 

4.

Clogged dust inlet port.

 

 

and remove obstruction.

Cleaner Won't

5.

Clogged hose.

 

5.

Remove obstruction.

Pick Up

6.

Broken belt.

6.

Replace belt.

 

7.

Hose not inserted fully.

 

7.

Push hose in securely.

 

8.

Dirty filters.

 

8.

Clean / change filters.

 

9.

HEPA Type filter and filter ring

 

9.

Clean or replace HEPA Type

 

 

needs cleaning or replacing.

 

 

 

filter and filter ring.

 

 

 

 

 

 

 

 

 

Cleaner Picks

 

 

 

 

Up Moveable

1.

Wrong pile height setting.

1.

Adjust setting.

Rugs Or Pushes

 

 

 

 

Too Hard

 

 

 

 

 

 

 

 

 

Agitator Does

1.

Broken belt.

1.

Replace belt.

2.

Check belt changing and

Not Turn

2.

Belt installed incorrectly.

 

agitator cleaning.

 

 

 

 

 

 

 

 

 

Air Flow

1.

Attachment use restricts air

 

 

Restricted With

 

flow.

1.

Check attachment.

Attachment Use

2.

New carpet debris clogging air

2.

Remove obstruction.

Sound Changes

 

path.

 

 

 

 

 

 

 

1.Do not operate the vacuum cleaner too close to heaters, or radiators.

2.Before inserting the power plug into the wall outlet, make sure that your hands are dry.

3.Do not vacuum any liquids.

4.Keep hair, loose clothing, fingers, feet and all parts of body away from openings, rotating agitator and other moving parts.

5.When pulling out the power plug from the wall outlet, pull the plug not the power cord.

6.Do not pick up anything that is burning or smoking such as cigarettes, matches or hot ashes.

7.Do not run appliance over power cord.

8.Do not use without dust cup (container) or filters in place.

9.Before you start vacuuming, make sure to remove large or sharp objects that might damage the vacuum.

Note: This vacuum cleaner is equipped with a plug and power cord that retract automatically. If the cord or plug get damaged, it must be replaced by a qualified technician.

Warning: Hold the plug when rewinding the cord. Do not allow the cord to whip when rewinding.

9