vThe ThinkScribe digital notepad assembly (02K5881) is defective.
3.Run Diagnostics and select ThinkScribe. If the device fails any of the tests, the ThinkScribe digital notepad assembly (02K5881) is defective.
4.Run Interactive Tests, and select ThinkScribe LCD Test. If the device fails any of the tests, the ThinkScribe digital notepad assembly (02K5881) is defective.
5.Run Interactive Tests and select ThinkScribe LED Test. If the device fails any of the tests, the ThinkScribe digital notepad assembly (02K5881) is defective.
6.Run Interactive Tests and select ThinkScribe Interactive Test.
7.Drag the pen from center top to center bottom and from center left to center right of ThinkScribe digital
notepad. If all position were detected properly:
v Both ThinkScribe digital notepad and digital pen are OK.
If one or more positions were not detected properly, the ThinkScribe digital notepad assembly (02K5881) is defective. If all positions were not detected properly:
vDigital pen (02K5633) battery is depleted, or
vDigital pen (02K5633) is defective, or
vThe ThinkScribe digital notepad assembly (02K5881) is defective.
If the
vReplace the digitizer pen (02K5633).
Intermittent problems
Intermittent system hang problems can be due to a variety of causes that have nothing to do with a hardware defect, such as cosmic radiation, electrostatic discharge, or software errors. FRU replacement should be considered only when a problem recurs.
When analyzing an intermittent problem, do the following:
1.Run the diagnostic test for the system board in loop mode at least 10 times.
2.If no error is detected, do not replace any FRUs.
3.If any error is detected, replace the FRU shown by the FRU code. Rerun the test to verify that no more errors exist.