Symptom-to-FRU index
The symptom-to-FRU index in this section lists symptoms
and errors and their possible causes. The most likely
cause is listed first, in boldface type.
Note: Do the FRU replacement or other actions in the
sequence shown in the column headed “FRU or
action, in sequence.”If replacing a FRU does not
solve the problem, put the original part back in the
computer.Do not replace a nondefective FRU.
This index can also help you determine, during regular
servicing, what FRUs are likely to need to be replaced
next.
Anumeric error is displayed for each error detected in
POST or system operation. In the displays, ncan be any
number.
If no numeric code is displayed, check the narrative
descriptions of symptoms. If the symptom is not described
there, go to “Intermittent problems”on page 48.
Note
For an IBM device not supported by diagnostic
codes in the ThinkPad notebook computers, see the
manual for that device.
Numeric error codesSymptomor error FRUor action, in sequence
0175
BadCRC1, stop POST task —
TheEEPROM checksum is not
correct.
Systemboard.
0187
EAIAdata access error —The
accessto EEPROM has failed.
Systemboard.
0188
InvalidRFID serialization
informationarea or bad CRC2
—TheEEPROM checksum is
notcorrect.
Systemboard.
0189
InvalidRFID configuration
informationarea —The
EEPROMchecksum is not
correct.
Systemboard.