PC/104-PlusCOM-1460 Module

 

 

 

 

A.1 Electrical and Environmental Specifications

The following section provides tables and illustrations showing the electrical, mechanical and environmental specifications for the COM-1460 module.

In the following tables you will find:

Operating Characteristics

Electrical operating characteristics

Operating temperature range

Absolute maximum ratings

MTBF

Operating Characteristics

Electrical Operating Characteristics

The board needs the following voltages to operate properly:

PCI/104-Plus +5V

External Power +8V - +40V (usually +12V)

Current Draw: 450mA @+5V (max)

Note. This module is not warranted against damage caused by overheating due to improper or insufficient cooling or airflow.

Operating Temperature Range

For proper operation of the module, the ambient air temperature must remain inside this range: 0°C to +60°C (+32°F to +140°F).

Absolute Maximum Ratings

 

Table 5.

Absolute Maximum Ratings

 

 

 

 

 

 

 

 

Supply Voltage:

 

Vcc: 0.00 to 7.00V

 

 

 

 

 

 

 

 

 

Storage Temperature Range:

 

 

-40°C to +85°C (-40°F to +185°F)

 

 

 

 

 

 

 

 

 

 

Non-Condensing Relative Humidity:

 

<95% at 40°C (+104°F)

 

 

 

 

 

 

 

 

 

 

 