EverFocus EDSR1600 instruction manual Instant Recording, Alarm Recording, Disk 39 GB

Models: EDSR1600

1 57
Download 57 pages 34.05 Kb
Page 31
Image 31

Recording

7.1 INSTANT RECORDING

 

 

 

 

 

Press REC key to start continuous recording with setting of “NORMAL RECORD”.

 

 

 

 

 

The recording rate and recording quality are set in the RECORD SETTING MENU.

REC

 

 

 

 

 

 

The LCD screen on the front panel of DVR will display as follows:

2003/11/23

21:56:47

REC HDD1 70% 50 IPS 21:56:52

Display shows operation status, active HDD, record position on active HDD, record frame rate ant current time.

REC, Maximum 60 (NTSC) / 50 (PAL) fields will also show on the main monitor display if you press the DISPLAY key to show camera title and date/time.

Press STOP key to stop recording.

STOP Since the DVR had Duplex feature, STOP key can be activated both in Playing back and Recording. In Duplex mode first STOP will stop playback, second STOP will stop recording.

When the HDD is full, the machine will Stop recording automatically or

from the beginning of the HDD. It depends on the setting in RECORD SETTING MENU.

7.2 ALARM RECORDING

When the ALARM OPERATION setting is “ON”, the DVR will automatically record

when alarm occurs , and will automatically stops recording at the end of the alarm duration period.

As example, we set ALARM RECORDING SPEED on 50 IPS PAL field, the screen will show as below,

A.REC (50IPS)

DISK: 39 GB

Instant recording and timer recording will stop when an alarm occurs.

Please refer details in RECORD SETTING MENU (page 19).

26

Page 31
Image 31
EverFocus EDSR1600 instruction manual Instant Recording, Alarm Recording, Disk 39 GB