PROBLEM

CAUSE

CORRECTION

 

Pressure reading

It is normal for "some"

If there is an excessive amount

 

on the regulated

pressure drop to occur.

of pressure drop when the

 

pressure gauge

 

accessory is used, adjust the

 

 

regulator as instructed in the

 

(if equipped)

 

 

 

Operation section.

 

drops when an

 

 

 

NOTE: Adjust the regulated

 

accessory is

 

 

 

pressure under flow condi-

 

used.

 

 

 

tions (while accessory is being

 

 

 

 

 

 

used).

 

 

 

 

 

Air leak from

Possible defect in safety

Operate safety valve manually

 

safety valve.

valve.

by pulling on ring. If valve still

 

 

 

leaks, it should be replaced.

 

 

 

 

 

Compressor is

Prolonged excessive use

Decrease amount of air usage.

 

not supplying

of air.

Check the accessory air re-

 

enough air to

Compressor is not large

 

operate acces-

enough for air requirement.

quirement. If it is higher than

 

sories.

 

the SCFM or pressure supplied

 

 

 

by your air compressor, you

 

 

 

need a larger compressor.

 

 

Hole in hose.

Check and replace if required.

 

 

Check valve restricted.

Remove and clean, or replace.

 

 

Air leaks.

Tighten fittings.

 

 

Restricted air intake filter.

Clean or replace air intake

 

 

 

filter. Do not operate the air

 

 

 

compressor with the filter re-

 

 

 

moved. Refer to the "Air Filter"

 

 

 

paragraph in the Maintenance

 

 

 

section.

 

 

Loose belt.

Check belt tension, see Adjust-

 

 

 

ing Belt Tension in the Mainte-

 

 

 

nance section.

 

 

 

 

 

Restricted air

Dirty air filter.

Clean or replace. See Air Filter

 

intake.

 

paragraph in the Maintenance

 

 

 

section.

 

 

 

 