Excell Precision Specifications, Glossary, Duty Cycle, Accessories, Model No E7540

Models: E7540

1 78
Download 78 pages 54.72 Kb
Page 8
Image 8

SPECIFICATIONS

Model No.

E7540

Running Horsepower

6.0

Voltage-Single Phase

240V

Minimum Branch Circuit Requirement

30 amps

*Fuse Type

Time Delay

Air Tank Capacity, Gallons

80 ASME, Vertical

Approximate Cut-in Pressure

140 PSIG

Approximate Cut-out Pressure

175 PSIG

SCFM @ 100 psig

14.0

SCFM @ 175 psig

13.5

GLOSSARY

Become familiar with these terms before operating the unit. CFM: Cubic feet per minute.

SCFM: Standard cubic feet per minute; a unit of measure of air delivery.

PSIG: Pounds per square inch gauge; a unit of measure of pressure.

Code Certification: Products that bear one or more of the following marks: UL, CUL, ETL, CETL, have been evaluated by OSHA certified independent safety laboratories and meet the applicable Underwriters Laboratories Standards for Safety.

Cut-In Pressure: While the motor is off, air tank pressure drops as you continue to use your accessory. When the tank pressure drops to a certain low level the motor will restart automatically. The low pressure at which the motor automati- cally restarts is called "cut-in" pressure.

Cut-Out Pressure: When an air compressor is turned on and begins to run, air pressure in the air tank begins to build. It builds to a certain high pressure before the motor automatically shuts off - protecting your air tank from pressure higher than its capacity. The high pressure at which the motor shuts off is called "cut-out" pressure.

Branch Circuit: Circuit carrying electricity from electrical panel to outlet.

To Lock Out Power: Place a lock on the line power switch so no one else can turn on the power.

DUTY CYCLE

This air compressor pump is capable of running continuously. However, to pro- long the life of your air compressor, it is recommended that a 50%-75% average duty cycle be maintained; that is, the air compressor pump should not run more than 30-45 minutes in any given hour.

ACCESSORIES

Accessories for this unit are available at the store the unit was purchased.

A18791

8-ENG

Page 8
Image 8
Excell Precision operation manual Specifications, Glossary, Duty Cycle, Accessories, Model No E7540