Appendix A Cisco XR 12406 Router Technical Specifications and Warnings

Compliance Information

Table A-7

Immunity Tests

 

 

 

 

Test Type or Specification

Applies to

Class/Level/Criteria

 

 

 

Electrostatic Discharge

System/enclosure

Level 4/8KV contact, 15KV air/B

EN61000-4-2:1995

 

 

 

 

 

Radiated Immunity

System/enclosure

Level 3/10V/m/A

IEC61000-4-3:1995

 

1KHz 80% AM

ENV50140:1993

 

(80MHz - 1 GHz)

 

 

 

 

Fast Transients

 

AC power lines

Level 4/4 KV 2.5 kHz Rep Freq/B

EN61000-4-4:1995

 

 

 

 

DC lines

Level 4/4 KV 2.5 kHz Rep Freq/B

 

 

Signal lines

Level 4/1 KV 5kHz Rep Freq/A

 

 

 

Level 4/2 KV 5kHz Rep Freq/B

 

 

 

 

Surge Immunity

 

AC power line (live-neutral)

Class 4/2KV/B

EN61000-4-5:1995

2 ohms

 

 

 

AC power line (live-earth)

Class 4/4KV/B

 

 

12 ohms

 

 

 

DC power line (live-earth)

Class 4/500V/B

 

 

DC Power line (return-earth)

Class 4/500V/B

 

 

Signal lines 2 ohms

Indoor: 500V

 

 

 

Outdoor: 4KV/R

 

 

 

Conducted RF Immunity

AC power line

Level 3/10V/A

EN61000-4-6:1996+

DC power line

(150kHz-80MHz)

ENV50141:1993

Signal lines

 

 

 

 

Voltage Dips + Sag

AC power lines

30% 10 ms (0.5 period)/B

Interruptions

 

 

30% 5000ms (25 periods)

AC Power Lines

 

 

60% 100 ms (5 periods)/C

EN61000-4-11:1995

 

60% 1000 ms (50 periods)

 

 

 

>95% 10ms (0.5 period)/C

 

 

 

>95% 5000 ms (250 periods)

 

 

 

 

 

 

Cisco XR 12406 Router Installation Guide

 

 

 

 

 

 

OL-13831-01

 

 

A-7

 

 

 

Page 205
Image 205
Cisco Systems XR 12406 manual Test Type or Specification Applies to Class/Level/Criteria