Chapter 5 Maintaining the Router

Removing and Replacing a DC PDU

Step 5 Disconnect the DC power leads from the PDU power connector blocks in the following order (Figure 5-21):

a.Negative lead from the top port.

b.Positive lead from the middle port.

c.Ground lead from the bottom port.

d.Repeat these steps for the second power connector block.

Warning To prevent injury and damage to the equipment, always remove the source DC power leads and ground from the power shelf terminals in the following order:

(a) negative (–), (b) positive (+), (c) ground.

Figure 5-21 Disconnecting the DC Power Leads

POWER A

4

+ GND

1

2

3

57993

1

Negative terminal port

3

Ground terminal port

 

 

 

 

2

Positive terminal port

4

Terminal port connector screws

 

 

 

 

 

 

Cisco XR 12406 Router Installation Guide

 

 

 

 

 

 

OL-13831-01

 

 

5-35

 

 

 

Page 175
Image 175
Cisco Systems XR 12406 manual Negative -, b positive +, c ground, Disconnecting the DC Power Leads