Chapter 5 Maintaining the Router

Removing and Replacing a DC PEM

Step 1 Power off the faulty PEM (item 3 in Figure 5-15).

Figure 5-15 DC Power Entry Module Components

OUTPUT

INPUT

MISWIRE

OK

OK

 

 

OUTPUT

INPUT MIS

 

OK

WIRE

 

OK

5

4

2 4

62203

31

1

2

3

DC PEM

4

Captive screws/release levers

 

 

 

Handle

5

Cooling fan

 

 

 

Power On/Off switch

6

AC input/DC output/miswire status indicators

 

 

 

Step 2 Power off the circuit breaker assigned to the power supply.

Step 3 Remove the power supply from the chassis (Figure 5-16):

a.Loosen the captive screw on each ejector lever.

b.Pivot the levers open to release the power supply from its bay.

c.Slide the power supply out of its bay while supporting it with your other hand.

Warning The power supply weighs approximately 10 lb (4.5 kg). Use two hands to remove the power supply.

 

 

Cisco XR 12406 Router Installation Guide

 

 

 

 

 

 

OL-13831-01

 

 

5-27

 

 

 

Page 167
Image 167
Cisco Systems XR 12406 manual Power off the faulty PEM item 3 in Figure, Dc Pem