Chapter 6 Fault Code Information and MaintenanceManual background

Fault Name

Fault Descriptions

Corrective Actions

 

OC hardware error

 

 

CC (current clamp)

 

 

OV hardware error

 

 

 

Return to the factory.

 

GFF hardware error

 

 

OV or LV

 

 

Current sensor error

 

 

U-phase error

 

 

 

Return to the factory.

 

W-phase error

 

 

Phase Loss

Check input phase wiring for loose contacts.

 

Software protection failure

Return to the factory.

 

 

1. Check parameter settings (Pr.116) and

 

 

AVI/ACI wiring.

 

PID feedback signal error

2. Check for possible fault between

 

 

system response time and the PID

 

 

feedback signal detection time (Pr.123)

6-4

Revision May 2008, ME14, SW V3.04

Page 135