Chapter 4 Parameters

 

 

 

Parameter

Explanation

Settings

Factory

Customer

 

 

Setting

 

 

Pr.08

Minimum Output Freq

0.10 to 20.00Hz

1.50

 

 

 

 

 

 

 

 

 

 

 

 

115V/230V: 0.1 to 255.0V

10.0

 

 

 

Pr.09

Minimum Output

 

 

 

 

 

460V: 0.1 to 510.0V

20.0

 

 

 

Voltage

 

 

 

 

 

 

 

 

 

 

 

575V: 0.1 to 637.0V

26.1

 

 

 

 

 

 

 

 

 

 

Pr.10

Acceleration Time 1

0.1 to 600.0 sec or 0.01 to 600.0 sec

10.0

 

 

 

 

 

 

 

 

 

 

Pr.11

Deceleration Time 1

0.1 to 600.0 sec or 0.01 to 600.0 sec

10.0

 

 

 

 

 

 

 

 

 

 

Pr.12

Acceleration Time 2

0.1 to 600.0 sec or 0.01 to 600.0 sec

10.0

 

 

 

 

 

 

 

 

 

 

Pr.13

Deceleration Time 2

0.1 to 600.0 sec or 0.01 to 600.0 sec

10.0

 

 

 

 

 

 

 

 

 

 

Pr.14

Accel S-curve

00 to 07

00

 

 

 

 

 

 

 

 

 

 

Pr.15

Jog Accel/Decel Time

0.1 to 600.0 sec or 0.01 to 600.0 sec

1.0

 

 

 

 

 

 

 

 

 

 

Pr.16

Jog Frequency

0.00 to 400.0 Hz

6.00

 

 

 

 

 

 

 

 

 

 

Pr.17

1st Step Speed Freq.

0.00 to 400.0Hz

0.00

 

 

 

 

 

 

 

 

 

 

Pr.18

2nd Step Speed Freq.

0.00 to 400.0Hz

0.00

 

 

 

 

 

 

 

 

 

 

Pr.19

3rd Step Speed Freq.

0.00 to 400.0Hz

0.00

 

 

 

 

 

 

 

 

 

 

Pr.20

4th Step Speed Freq.

0.00 to 400.0Hz

0.00

 

 

 

 

 

 

 

 

 

 

Pr.21

5th Step Speed Freq.

0.00 to 400.0Hz

0.00

 

 

 

 

 

 

 

 

 

 

Pr.22

6th Step Speed Freq.

0.00 to 400.0Hz

0.00

 

 

 

 

 

 

 

 

 

 

Pr.23

7th Step Speed Freq.

0.00 to 400.0Hz

0.00

 

 

 

 

 

 

 

 

 

 

Pr.24

Reverse Operation

00: Enable REV operation

00

 

 

 

Inhibition

01: Disable REV operation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

00: Disable

 

 

 

 

 

 

 

 

 

 

 

Pr.25

Over-Voltage Stall

115V/230V: 330 to 450 Vdc

390

 

 

 

 

 

 

 

 

Prevention

460V: 660 to 900 Vdc

780

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

575V: 825 to 1025 Vdc

975

 

 

 

 

 

 

 

 

 

 

 

Over-current Stall

00: Disable

 

 

 

 

Pr.26

Prevention during

150

 

 

 

20% to 200%

 

 

 

 

Acceleration

 

 

 

 

 

 

 

 

 

 

 

Over-current Stall

00: Disable

 

 

 

 

Pr.27

Prevention during

150

 

 

 

20% to 200%

 

 

 

 

Operation

 

 

 

 

 

 

 

 

 

 

Pr.28

DC Braking Current

00 to 100 %

00

 

 

 

Level

 

 

 

 

 

 

 

 

 

Pr.29

DC Braking during

0.0 to 5.0 sec

0.0

 

 

 

Start-up

 

 

 

 

 

 

 

 

Revision May 2008, ME14, SW V3.04

4-3