Delta Electronics VFD-M Motor Stalls during Acceleration, The Motor does not Run as Expected

Models: VFD-M

1 173
Download 173 pages 14.33 Kb
Page 129
Image 129
5.11 Motor Stalls during Acceleration

Chapter 5 TroubleshootingCheck if the inertia

5.11 Motor Stalls during Acceleration

Motor stalls during acceleration

Thicken or shorten the wiring between the motor and AC motor drive

Reduce load or increase the capacity of AC motor drive

 

Check if acceleration

Yes

 

time is too short

 

 

 

 

No

 

Check if the inertia

Yes

of the motor and load

 

 

 

is too high

 

 

 

 

No

 

 

 

 

 

Yes

 

Check for low voltage

 

 

at input

 

 

 

 

No

 

 

 

 

 

Yes

Check if the load torque

 

is too high

 

of the motor and load Increase setting time

Yes

Use special motor?

No

Reduce load or increase the capacity of AC motor drive

 

No

 

 

 

 

 

 

 

 

Maybe AC motor drive has

Check if the torque

 

 

 

Yes

 

malfunction or misoperation

compensation is suitable

 

 

 

due to noise. Please contact

 

No

 

 

 

DELTA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Increase torque compensation

 

 

 

 

 

 

 

 

 

5.12 The Motor does not Run as Expected

Motor does not run

 

Check Pr. 04 to Pr. 09

No

Adjust Pr.04 to Pr.09

 

and torque compensation

 

 

as expected

 

 

 

 

 

 

 

 

 

settings

 

 

 

 

 

and lower torque compensation

 

 

 

 

 

 

 

 

 

 

Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Yes

 

 

 

Please use specific motor

 

Run in low speed continuously

 

 

 

 

 

 

 

 

 

 

 

 

 

No

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Yes

 

 

 

 

 

 

 

 

 

 

Is load too large

 

 

 

 

 

 

 

 

Reduce load or increase the

 

 

 

 

 

 

 

 

 

 

No

 

 

capacity of AC motor drive

 

 

 

 

 

 

 

 

 

 

 

Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Check if output voltage of U, V, W

 

 

 

Motor has malfunction

 

 

is balanced

 

 

 

 

 

 

 

 

No

Maybe AC motor drive has malfunction or misoperation due to noise. Please contact DELTA.

5-8

Revision May 2008, ME14, SW V3.04

Page 129
Image 129
Delta Electronics VFD-M Motor Stalls during Acceleration, The Motor does not Run as Expected, Troubleshooting, is too high