Chapter 4 Parameters
When the JOG function is activated, the AC drive will accelerate from Minimum Output Frequency (Pr.08) to Jog Frequency (Pr.16). Drive must be in “stop” status for the operator to activate the JOG function. Likewise, during Jog operation, other commands cannot be accepted through the keypad but FORWARD, REVERSE and STOP. The JOG function can be remotely activated when the Jog terminal is closed, and if the Jog terminal opens, the AC drive will decelerate from Jog Frequency to zero. The accel / decel time is entered as Jog Accel / Decel Time (Pr.15).
Frequency
Jog
Freq.
Pr.16
|
|
|
|
|
|
|
|
|
|
|
|
|
| Time |
|
|
|
| Pr. 15 |
|
|
|
|
| Pr. 15 |
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Acceleration Time | Deceleration Time | ||||||||||||
Jog operation |
|
|
|
|
|
| ON |
|
|
|
| OFF | ||
command |
|
|
|
|
|
|
|
|
|
| ||||
Pr.17 | 1st Step Speed Frequency | Unit: 0.1 Hz | ||
Pr.18 | 2nd Step Speed Frequency | Unit: 0.1 Hz | ||
Pr.19 | 3rd Step Speed Frequency | Unit: 0.1 Hz | ||
Pr.20 | 4th Step Speed Frequency | Unit: 0.1 Hz | ||
Pr.21 | 5th Step Speed Frequency | Unit: 0.1 | Hz | |
Pr.22 | 6th Step Speed Frequency | Unit: 0.1 | Hz | |
Pr.23 | 7th Step Speed Frequency | Unit: 0.1 | Hz | |
| Settings 0.00 to 400.0Hz | Factory Setting: 0.00 | Hz | |
|
|
|
|
|
Revision May 2008, ME14, SW V3.04 |