Delta Electronics VFD-M manual Parameter, Explanation, Settings, Factory

Models: VFD-M

1 173
Download 173 pages 14.33 Kb
Page 44
Image 44
Manual background

 

 

 

Chapter 4 Parameters

 

 

 

Parameter

Explanation

Settings

Factory

Customer

 

 

Setting

 

 

 

 

00: Disable PLC operation

 

 

 

 

 

 

01: Execute one program cycle

 

 

 

 

Pr.78

PLC Operation Mode

02: Continuously execute program cycles

00

 

 

 

03: Execute one program cycle step by step

 

 

 

 

 

 

 

 

 

 

 

04: Continuously execute one program cycle

 

 

 

 

 

 

step by step

 

 

 

 

 

 

 

 

 

 

 

Pr.79

PLC FWD/REV

00 to 127

00

 

 

 

Motion

 

 

 

 

 

 

 

 

 

Pr.80

Identity Code of the

Read only

##

 

 

 

AC Motor Drive

 

 

 

 

 

 

 

 

 

Pr.81

Time Duration of 1st

00 to 9999 sec

00

 

 

 

Step Speed

 

 

 

 

 

 

 

 

 

Pr.82

Time Duration of 2nd

00 to 9999 sec

00

 

 

 

Step Speed

 

 

 

 

 

 

 

 

 

Pr.83

Time Duration of 3rd

00 to 9999 sec

00

 

 

 

Step Speed

 

 

 

 

 

 

 

 

 

Pr.84

Time Duration of 4th

00 to 9999 sec

00

 

 

 

Step Speed

 

 

 

 

 

 

 

 

 

Pr.85

Time Duration of 5th

00 to 9999 sec

00

 

 

 

Step Speed

 

 

 

 

 

 

 

 

 

Pr.86

Time Duration of 6th

00 to 9999 sec

00

 

 

 

Step Speed

 

 

 

 

 

 

 

 

 

Pr.87

Time Duration of 7th

00 to 9999 sec

00

 

 

 

Step Speed

 

 

 

 

 

 

 

 

 

Pr.88

Communication

01 to 254

01

 

 

 

Address

 

 

 

 

 

 

 

 

 

 

 

00: 4800 bps

 

 

 

 

Pr.89

Transmission Speed

01: 9600 bps

01

 

 

 

02: 19200 bps

 

 

 

 

 

 

 

 

 

 

 

03: 38400 bps

 

 

 

 

 

 

 

 

 

 

 

 

 

00: Warn and Continue Operating

 

 

 

 

Pr.90

Transmission Fault

01: Warn and RAMP to Stop

03

 

 

 

Treatment

02: Warn and COAST to Stop

 

 

 

 

 

 

 

 

 

 

03: Keep Operation without Warning

 

 

 

 

 

 

 

 

 

 

 

Pr.91

Time Out Detection

0.0: Disable

0.0

 

 

 

0.1 to 120.0 sec

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

00: MODBUS ASCII mode, <7,N,2>

 

 

 

 

 

 

01: MODBUS ASCII mode, <7,E,1>

 

 

 

 

Pr.92

Communication

02: MODBUS ASCII mode, <7,O,1>

00

 

 

 

Protocol

03: MODBUS RTU mode, <8,N,2>

 

 

 

 

 

 

 

 

 

 

04: MODBUS RTU mode, <8,E,1>

 

 

 

 

 

 

05: MODBUS RTU mode, <8,O,1>

 

 

 

 

 

 

 

 

 

 

Revision May 2008, ME14, SW V3.04

4-9

Page 44
Image 44
Delta Electronics VFD-M manual Parameter, Explanation, Settings, Factory