Chapter 4 Parameters
4.3 Description of Parameter Settings
This parameter can be set during operation.
| Pr.00 | Source of Frequency Command |
Factory Setting: 00
Settings 00 Master Frequency determined by digital keypad.
01Master frequency determined by 0 to +10 V input
02Master frequency determined by 4 to 20mA input
03Master frequency determined by
04Master frequency determined by potentiometer on digital keypad.
Pr.01 | Source of Operation Command | |
|
| Factory Setting: 00 |
| Settings 00 | Operation instructions determined by the Digital Keypad. |
01Operation instructions determined by the External Control Terminals. Keypad STOP key is effective.
02Operation instructions determined by the External Control Terminals. Keypad STOP key is not effective.
03Operation instructions determined by the
04Operation instructions determined by the
Refer to Pr.38 to Pr.42 for more details.
Pr.02 | Stop Method |
Factory Setting: 00
Settings 00 | Ramp to stop |
01 | Coast to stop |
|
|
This parameter determines how the motor is stopped when the AC drive receives a valid stop
command.
1.Ramp: The AC drive decelerates the motor to Minimum Output Frequency (Pr.08) and then stops according to the deceleration time set in Pr.11 or Pr.13.
2.Coast: The AC drive will stop the output instantly, and the motor will coast to stop.
Revision May 2008, ME14, SW V3.04 |