Appendix A Specifications
There are 115V, 230V, 460V and 575V models in the
Voltage Class
Model Number
Max. Applicable Motor Output (kW)
Max. Applicable Motor Output (hp)
Rating | Rated Output Capacity (kVA) | |
Rated Output Current (A) | ||
| ||
Output | Maximum Output Voltage (V) | |
Carrier Frequency (kHz) | ||
Rating | Output Frequency (Hz) | |
Rated Voltage, Frequency | ||
| Rated Input Current (A) | |
Input | Voltage Tolerance | |
| ||
| Frequency Tolerance |
Cooling Method
Weight (kg)
| 115V Class |
|
002 | 004 | 007 |
0.2 | 0.4 | 0.75 |
0.25 | 0.5 | 1.0 |
0.6 | 1.0 | 1.6 |
1.6 | 2.5 | 4.2 |
| 0.1~400 Hz |
|
|
| |
| Single phase |
|
6 | 9 | 16 |
Single phase, |
| |
±10%
±5% (47~63Hz) Fan Cooled
1.51.51.5
Voltage Class
Model Number
Max. Applicable Motor Output (kW)
Max. Applicable Motor Output (hp)
Rating | Rated Output Capacity (kVA) | |
Rated Output Current (A) | ||
| ||
Output | Maximum Output Voltage (V) | |
Carrier Frequency (kHz) | ||
| Output Frequency (Hz) | |
| Rated Input Current (A) | |
Rating | Input Current for | |
Power | ||
| Models when Using | |
Input | Rated Voltage, Frequency |
Voltage Tolerance
Frequency Tolerance
Cooling Method
Weight (kg)
Revision June 2007, 0ELE, V1.00
230V Class
004 |
| 007 | 015 |
| 022 | 037 | 055 |
0.4 |
| 0.75 | 1.5 |
| 2.2 | 3.7 | 5.5 |
0.5 |
| 1.0 | 2.0 |
| 3.0 | 5.0 | 7.5 |
1.0 |
| 1.9 | 2.7 |
| 3.8 | 6.5 | 9.5 |
2.5 |
| 5.0 | 7.0 |
| 10 | 17 | 25 |
|
|
| |||||
|
|
| 0.1~400 Hz |
|
| ||
|
|
|
|
|
|
| |
|
|
|
| ||||
6.3/2.9 |
| 11.5/7.6 | 15.7/8.8 |
| 27/12.5 | 19.6 | 28 |
3.2 |
| 6.3 | 9.0 |
| 12.5 | ||
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
| |||||
|
| ||||||
|
| 50/60Hz | |||||
|
|
|
|
|
| ||
±10% (180~264 VAC)
±5% (47~63 Hz)
Fan Cooled
2.2/1.5 | 2.2/1.5 | 2.2/1.5 | 3.2/2.2 | 3.2 | 3.2 |