5.10 Motor Speed cannot be Changed

Chapter 5 TroubleshootingManual background

5.10 Motor Speed cannot be Changed

 

 

 

Motor can run but

 

 

 

 

 

 

 

cannot change speed

 

 

 

 

 

 

 

 

 

 

 

 

Modify the setting

Yes

 

Check if the setting of the

 

 

 

 

 

max. frequency is too low

 

 

 

 

 

 

 

 

 

No

 

 

 

No

 

 

 

 

 

 

 

 

 

 

 

If the setting of frequency

Yes

 

 

 

 

is out of range(upper/lower)

 

Modify the setting

 

 

 

 

 

bound

 

 

 

 

 

 

 

 

Yes

If the setting of

Pr.17 to Pr.23

 

 

are the same

No

No

Press UP/DOWN key to see if speed has any change

If there is any change of the signal that sets frequency (0-10V and 4-20mA)

Yes

Yes

No

Check if the wiring between

 

 

M0~M5 to GND is correct

No

 

 

No

Yes

Connect correctly

Check if frequency for

 

each step is different

No

Yes

 

No

Check if the wiring of external terminal is correct

Yes

Change defective potentiometer

No If accel./decel. time is very long

Yes

Please set suitable accel./decel. time by load inertia

Change frequency setting

Maybe AC motor drive has malfunction or misoperation due to noise. Please contact DELTA.