B.1 Electrical and Environmental

The following sections provide tables and illustrations showing the electrical and environmental specifications.

B.1.1 Electrical

The AMC.1-HDD SAS disk shall consume no more than the following from the system supplies under normal operating conditions.

TABLE B-1Electrical Specifications

SUPPLY

SAS (Max

Management power

Less than 100 mA

 

 

+12V (spin up less than 8 secs)

1.5A (18W)

 

 

+12V normal operating

1.0A (12W)

 

 

+12V (idle)

0.75A (9W)

 

 

Off State

Less than 0.4W

 

 

Max current draw

1.5A during spin-up

 

 

B.1.2 Environmental

The environmental values are listed in the following table.

TABLE B-2Environmental Specifications

Specification

 

Enterprise SAS

 

 

 

Temperature

Operating (ambient)

5ºC to 55ºC

 

 

 

 

Disk enclosure surface

5ºC to 60ºC (operating)

 

Nonoperating

–40ºC to 70ºC

 

Gradient

3 ºC/min – (20ºC/hour)

 

 

 

Relative humidity

Operating

5% to 95%

 

Nonoperating

5% to 95%

 

Maximum wet bulb

29ºC (operating)

 

 

 

B-2Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010

Page 60
Image 60