B.1.3 Absolute Maximum Ratings

The following values are stress ratings only. Do not operate at these maximums. See Section B.1.4, “Normal Operating Ranges” on page B-4for normal operating conditions.

Payload voltage, +12V

0 VDC to +13.2 VDC

Management voltage, +3.3V

3.135 VDC to +3.465

 

VDC

Storage temperature

–40 to +70˚ Celsius

Noncondensing relative humidity

5% to 95% at 29˚ Celsius

 

 

B.1.4 Normal Operating Ranges

Description

Range

 

 

Nominal operating voltage

Operating temperatures*:

60m below sea level up to 1800m above sea level

from 1800m up to 4000m above sea level

Operating humidity

Idle power consumption (without links)

Maximum power consumption

+10.8 to +13.2 VDC payload power

3.135 VDC to +3.465 VDC management power

–5˚ to +55˚C

–5˚ to +40˚C

Less than 85% at 29˚C

9W

12W

*The MTBF will be significantly reduced if operated above 30˚C for more than 96 consecutive hours.

B.2 Reliability

Reliability prediction was done using Telcordia document SR-332, Issue 1. The prediction assumed 25˚ Celsius operating temperature with 100 percent duty cycle, in a ground-benign, controlled environment.

MTBF: 630,000 hours

One year limited warranty

B-4Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010