1.1.4Electrical and Environmental

See Appendix B for electrical and environmental requirements.

Caution – None of the integrated chips junction temperature should exceed 125˚C. The AMC requires air flow to meet this requirement. Testing should be done in the shelf to find the quantity of air flow needed. The recommended minimum air flow is

50 LFM.

1.2Unpacking

Check the shipping carton for damage. If the shipping carton or contents are damaged, notify the carrier and Sun. Retain the shipping carton and packing material for inspection by the carrier. Obtain authorization before returning any product to Sun. Refer to the Netra CP3000 Advanced Mezzanine Card PCIe SAS Controller and Hard Drive Getting Started Guide (820-7177) for return instructions.

Caution – This board must be protected from static discharge and physical shock. Never remove any of the socketed parts except at a static-free workstation. Use the antistatic bag shipped with the product to handle the board. Wear a wrist strap grounded through one of the system's ESD ground jacks when installing or servicing system components.

Chapter 1 Getting Started

1-3

Page 13
Image 13
Sun Microsystems CP3000 manual Unpacking, Electrical and Environmental