Delta Electronics VFD-M manual Parameter, Explanation, Settings, Factory

Models: VFD-M

1 173
Download 173 pages 14.33 Kb
Page 45
Image 45

Chapter 4 ParametersManual background

 

Parameter

Explanation

Settings

Factory

Customer

 

 

Setting

 

 

Pr.93

Accel 1 to Accel 2

0.01 to 400.0

0.00

 

 

 

Frequency Transition

0.00: Disable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pr.94

Decel 1 to Decel 2

0.01 to 400.0

0.00

 

 

 

Frequency Transition

0.00: Disable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pr.95

Auto Energy Saving

00: Disable auto energy saving

00

 

 

 

01: Enable auto energy saving

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pr.96

Counter Countdown

00 to 9999

00

 

 

 

Complete

 

 

 

 

 

 

 

 

 

Pr.97

Preset counter

00 to 9999

00

 

 

 

countdown

 

 

 

 

 

 

 

 

 

Pr.98

Total Time Count from

00 to 65535 days

Read

 

 

 

Power On (Days)

 

Only

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pr.99

Total Time Count from

00 to 1440 minutes

Read

 

 

 

Power On (Minutes)

 

Only

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pr.100

Software Version

 

##

 

 

 

 

 

 

 

 

 

 

 

 

00: Linear Accel/Decel

 

 

 

 

 

 

01: Auto Accel, Linear Decel

 

 

 

 

Pr.101

Auto Adjustable

02: Linear Accel, Auto Decel

00

 

 

 

Accel/Decel

03: Auto Accel/Decel

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

04: Linear Accel/Decel Stall Prevention

 

 

 

 

 

 

during Deceleration

 

 

 

 

 

 

 

 

 

 

 

 

 

00: AVR function enabled

 

 

 

 

Pr.102

Auto Voltage

01: AVR function disabled

00

 

 

 

Regulation (AVR)

02: AVR function disabled when stops

 

 

 

 

 

 

 

 

 

 

03: AVR function disabled when decel

 

 

 

 

 

 

 

 

 

 

 

 

Auto tune Motor

00: Disable

 

 

 

 

Pr.103

01: Auto tune for R1

00

 

 

 

Parameters

 

 

 

 

02: Auto tune for R1 + No Load testing

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pr.104

R1 value

00 to 65535 mΩ

00

 

 

 

 

 

 

 

 

 

 

Pr.105

Control Mode

00: V/F Control

00

 

 

 

01: Sensor-less Control

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pr.106

Rated Slip

0.00 to 10.00 Hz

3.00

 

 

 

 

 

 

 

 

 

 

Pr.107

Vector Voltage Filter

5 to 9999 (per 2ms)

10

 

 

 

 

 

 

 

 

 

 

Pr.108

Vector Slip

25 to 9999 (per 2ms)

50

 

 

 

Compensation Filter

 

 

 

 

 

 

 

 

 

Pr.109

Selection for Zero

00: No output

00

 

 

 

Speed Control

01: Control by DC voltage

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4-10

Revision May 2008, ME14, SW V3.04

Page 45
Image 45
Delta Electronics VFD-M manual Parameter, Explanation, Settings, Factory