Chapter 5 Maintaining the Router
Removing and Replacing the Blower Module
Troubleshooting the Blower Installation
Use the following procedure to troubleshoot the blower module if it is not operating properly after installation.
Caution To prevent overheating, do not operate the system without the blower module operational for more than a few minutes.
Step 1 Be sure the router is powered on and that all power cords are connected properly.
Step 2 Loosen the four captive screws and reseat the blower module to the chassis. Retighten the captive screws to ensure the blower module is properly seated to the backplane connector.
Step 3 Check the blower module status indicators:
•OK
•Fail
–If this indicator remains on and the blower module fans fail to operate normally after several attempts to reseat the blower module, replace the existing blower module with a spare.
–If the spare blower module also fails, power off the router and contact a Cisco service representative for assistance.
| Cisco XR 12406 Router Installation Guide |
|