Chapter 4 Troubleshooting the Installation

Troubleshooting an AC Power Subsystem

Troubleshooting an AC Power Subsystem

AC PEMs provide –48 VDC OUTPUT. The +5 VDC OUTPUT from the CSF powers the MBus module on each card in the system. The MBus module, in turn, control the DC-DC converters also present on each card in the system. The DC-DC converter takes –48 VDC from the power supply and converts it into +2.5, +3.3 and +5 VDC, which is distributed to the card circuitry.

AC PEMs are monitored by the MBus module and the RP for over- or undervoltage and over- or undercurrent conditions.

Begin checking the AC-input power subsystem by first looking at the LEDs on the AC-input power supplies. Figure 4-1 shows the location of the LEDs on the power supply.

Figure 4-1 AC-Input Power Supply LEDs

3

1

 

57916

2

5

4

1

2

3

AC-input power supply

Handle

Power standby switch

4Captive screws on release levers

5LEDs

 

Cisco XR 12406 Router Installation Guide

4-6

OL-13831-01

Page 118
Image 118
Cisco Systems XR 12406 manual Troubleshooting an AC Power Subsystem, AC-Input Power Supply LEDs