Chapter 1 Cisco XR 12406 Router Overview

Line Cards

Table 1-1

AC-Input Power Supply LED indicators (continued)

 

 

 

 

LED Label

Function

State

Description

 

 

 

 

DC

Output

On

Power supply is operating normally in a

 

Power

 

power-on condition.

 

 

 

 

 

 

Off

Power supply is operating in a fault

 

 

 

condition and shutdown has occurred.

 

 

 

 

DC Power Subsystem

The DC power subsystem consists of the following system components:

DC PDU (one)

DC-input PEMs (one for nonredundant operation; two for redundant operation)

Caution To ensure that the chassis configuration complies with the required power budgets, use the on-line power calculator. Failure to properly verify the configuration may result in an unpredictable state if one of the power units fails. Contact your local sales representative for assistance.

DC PDU

Facility DC power connects to DC-powered routers though the connector blocks on the DC PDU (Figure 1-8).

 

Cisco XR 12406 Router Installation Guide

1-20

OL-13831-01