4.1.25Fuel priming procedure:

a)Unit is equipped with an electric priming pump. Turn key on to let electric pump run for at least 30 seconds before starting.

b)Start engine using procedure in Section 3.3.2.

IMPORTANT: DO NOT over crank engine. Over cranking engine can damage the starter and/or the fuel solenoid. If engine does not start within 10 seconds allow electric pump to run for 30 seconds before cranking again.

4.1.26Change hydraulic system filter:

First Interval: 250 hrs.

Normal Interval: Yearly.

NOTE: Use only Exmark Part No.103-2146

a)Stop engine, wait for all moving parts to stop, and remove key. Engage parking brake.

b)Carefully clean area around filter. It is important that no dirt or contamination enter hydraulic system.

c)Unscrew filter to remove and allow oil to drain from reservoir.

IMPORTANT: Before reinstalling new filter, fill it with Mobil 1 15W-50 and apply a thin coat of oil on the surface of the rubber seal.

Turn filter clockwise until rubber seal contacts the filter adapter, then tighten the filter an additional 2/3 to 3/4 turn.

d)Fill reservoir as stated in Section 4.1.11.

CAUTION

POTENTIAL HAZARD

Raising the mower deck for service or maintenance relying solely on mechanical or hydraulic jacks could be dangerous.

WHAT CAN HAPPEN

The mechanical or hydraulic jacks may not be enough support or may malfunction allowing the unit to fall, which could cause injury.

HOW TO AVOID THE HAZARD

DO NOT rely solely on mechanical or hydraulic jacks for support. Use adequate jack stands or equivalent support.

e)Raise the drive wheels off of the ground and support with jack stands (or equivalent support) just high enough to allow drive wheels to turn freely.

f)Start engine and move throttle control ahead to full throttle position. Move the motion control levers to the full speed and run for several minutes. Shut down machine and recheck oil level.

Do not change hydraulic system oil (except for what can be drained when changing filter), unless it is felt the oil has been contaminated or been extremely hot.

Changing oil unnecessarily could damage hydraulic system by introducing contaminates into the system.

31

Page 36
Image 36
Exmark Frontrunner manual First Interval 250 hrs Normal Interval Yearly