Switcher Error Responses
When the switcher receives an SIS command and determines that it is valid, it performs the command and sends a response to the host device. If the switcher is unable to perform the command because the command is invalid or contains invalid parameters, the switcher returns an error response to the host. The error response codes are:
E01 — Invalid input channel number (too large)
E10 — Invalid command
E12 — Invalid output number (too large)
E13 — Invalid value (out of range)
Using the Command/Response Table
The command/response table begins on the next page. Lower case letters are acceptable in the command field only where indicated. Symbols are used throughout the table to represent variables in the command/response fields. Symbol definitions are provided on the next page and an
ASCII to HEX Conversion Table |
• |
Command/Response Table
Symbol Definitions:
Esc
X1
X2
X3
X4
X5
X6
X7
X9
X19
= Carriage return/line feed |
| Input and output numbers in |
| commands may be entered as | |
|
|
= Carriage return (no line feed) | either | ||
= W |
| All input and output numbers | |
| are specified as | ||
= Input number | 01 – 04 | ||
in the response. | |||
= Input number (for tie) | 0 – maximum number of inputs (0=disconnected) | ||
= Output number | 01 – 02 |
|
= Audio gain/attenuation
= Audio gain | 0dB thru 24dB (1dB/step) |
= Audio attenuation | 1dB thru 18dB (1dB/step) |
= 0 – 10 (0 to 5 seconds, 0.5 seconds/step) | |
= 0 or 1 | 1 = on and 0 = off |
= Controller software version number to second decimal place
X20
= Mute | 0 = No mute, 1 = Video mute, 2 = Audio mute, 3 = Video & Audio mute |
CrossPoint 42 HVA Matrix Switcher • Programmer’s Guide |