Figure 4-19 — Connecting to the IP address

Communication and Control, cont’d

3.. At the < to > prompt, enter the IP address of the

IPL M PDP-ES. (The default IP address is 192.168.254.254, but it may have been changed in the setup or configuration process. If it was changed, use the new address.) Telnet defaults to port 23.

Figure 4-19 — Connecting to the IP address

4.If passwords were set up for the connected system, you are prompted to log in as an administrator or a user. Otherwise the system responds with a <cr/lf>.

5.Once you are connected, you can enter SIS commands as desired.

6.When you are finished entering commands to the interface, enter CTRL + to close the open connection.

7.Enter “quit” at the command prompt to quit Telnet.

Direct access (port 2001)

Direct access allows a direct, one-to-one connection to the plasma via a reserved IP port number. When a TCP session is initiated to port 2001, all data sent and received passes directly to and from that port without any processing.

Using direct access

1.Open a direct access Telnet session by entering the IP address followed by a space, then a port number 2001 (e.g., 192.168.244.244 2001).

2.Send Pioneer commands directly to the Pioneer plasma.

For specific functionality details and supported commands, refer to the Pioneer Plasma documentation.

3.Close the Telnet session to end the direct access session.

4.Use port redirect to finish the process. See the next section for detailed instructions.

You can force the direct access session to close by logging on as administrator and entering “Esc 1 * 0CD Direct access (port 2001) .”

Port redirect

Using the port redirector, the card allows data to be sent and received directly to and from the display and back to the client (e.g., a PC or the MLC 206) without any processing.

1.Open another Telnet session (see the previous section for details).

2.Reestablish a pass-through by using the “set redirect mode” command:

Esc 2*1*500*3DCD Using direct access

Troubleshooting

Turn on the plasma display and the control devices (PC, laptop, etc.).

If the output Pioneer plasma cannot be remotely controlled, check the following:

Power connections

1.

Ensure that the Pioneer plasma is plugged in.

2.

If the Pioneer and the IPL M PDP-ES are receiving power,

 

its Power LED should be on.

Data connections

1.

Check the cabling connections and make adjustments as

 

needed. The Link LEDs on the IPL M PDP-ES and the

 

computer should be solid green if a network connection is

 

detected. If these LEDs are not lit, the cable is either faulty

or not plugged in; or the wrong type of cable is being used (refer to Connecting the Hardware, in chapter 3).

2.Try to ping the unit by entering ping 192.168.254.254 at the DOS command prompt; or use the Web address provided to you by your system administrator. If you get no response:

a.Make sure your unit is using the appropriate subnet mask and/or gateway IP address (check with your system administrator).

b.Make sure your PC does not have a software firewall program that might block the IP address of the unit.

4-30 IPL M PDP-ES • Communication and Control

IPL M PDP-ES • Communication and Control 4-31