Extron electronic 68-1021-01 Installation and Operation, cont’d, Panel Features and Cabling

Models: 68-1021-01

1 36
Download 36 pages 28.19 Kb
Page 9
Image 9
Installation and Operation, cont’d

Installation and Operation, cont’d

Push gently

Figure 2-3 — Inserting the IPL M PDP-ES card into the communication slot

CAUTION

Be very careful when inserting the card. Do not

 

use excessive force, and push the card in as straight

 

as possible; a crooked entry could damage the card

 

or the plasma.

2.When the card is seated securely in the slot, use the spring loaded thumb screws on either end of the card faceplate to secure the card in place.

Thumb screws

Figure 2-4 — Securing the IPL M PDP-ES

3.Affix the Extron IPL M PDP-ES sticker label (Extron part # 33-1154-01) to the display, covering the existing Pioneer label, as shown below.

Insure that the sticker is placed so that it completely covers the existing Pioneer label.

Figure 2-5 — The IPL M PDP-ES sticker label

Panel Features and Cabling

See figure 2-6 below for detailed information about connections, LEDs, and power.

RS-232

RESET

IPL M PDP-ES

ACT LINK

 

LAN

 

 

 

 

 

 

1

2

3

4

5

6

Figure 2-6 — IPL M PDP-ES interface card

Ethernet/LAN communication

With the use of Ethernet/LAN communication, the

IPL M PDP-ES can be used to control the plasma display. See chapter 4, Communication and Control, for more details.

1LAN Activity LED — The yellow LED blinks to indicate LAN activity.

2LAN connector — Plug an RJ-45 jack into this socket to connect the unit to a computer network. Use a straight- through cable to connect to a switch, hub, or router; and a crossover cable to connect directly to a PC.

3LAN Link LED — The green LED lights to indicate a good LAN connection.

Clip Down

1 2 3 4 5 6 7 8

RJ-45

 

Straight-through cable

 

Crossover cable

 

 

 

 

connector

 

Side 1

 

Side 2

 

Side 1

 

Side 2

 

 

 

 

 

 

 

 

Pin

Wire color

Pin

Wire color

Pin

Wire color

Pin

Wire color

 

 

1

White-orange

1

White-orange

1

White-orange

1

White-green

 

 

2

Orange

2

Orange

2

Orange

2

Green

 

 

3

White-green

3

White-green

3

White-green

3

White-orange

1 2 3 4 5 6 7 8

 

4

Blue

4

Blue

4

Blue

4

Blue

 

 

 

 

5

White-blue

5

White-blue

5

White-blue

5

White-blue

 

 

6

Green

6

Green

6

Green

6

Orange

 

Twisted

7

White-brown

7

White-brown

7

White-brown

7

White-brown

 

Pairs

8

Brown

8

Brown

8

Brown

8

Brown

 

 

7&8

1&2 3&6 4&5

Figure 2-7RJ-45 connector wiring

For best performance, use a shielded Ethernet cable.

Power

4On/Off indicator LED — The green LED lights to indicate that the card is receiving power. It also indicates different reset modes.

2-4

IPL M PDP-ES • Installation and Operation

IPL M PDP-ES • Installation and Operation

2-5

Page 9
Image 9
Extron electronic 68-1021-01 Installation and Operation, cont’d, Panel Features and Cabling, Ethernet/LAN communication