Installing the CSVEQ 100 D
The CSVEQ 100 D is a
NThe line driver must be installed into an Underwriters Laboratories (UL) approved electrical wall box. The box is not included with the line driver; the installer is responsible for obtaining and installing the box.
Preparing the site and installing the wall box
Choose a location that allows cable runs without interference. Allow enough depth for both the wall box and the cables. You may need to install the cables into the wall or conduits before installing the line driver.
The line driver can be installed in a standard
NThe cutout template shown in appendix B is not full size. Pay attention to the measurements shown on the template.
1. Mark the guidelines for the opening on the wall.
•If the line driver is to be installed in a wall box, place the box against the installation surface and draw a line on it around the outside of the box.
•If the line driver is to be installed without a wall box (fastening it directly to the wall), measure and mark the surface for the cutout area indicated in the cutout template.
2. Cut out the material from the marked area.
3. Check the opening size by inserting the wall box (if used) or the line driver (if no box is used) into the opening. The box and line driver should fit easily into the opening.
Enlarge or smooth the edges of the opening if needed.
4. Feed cables through the wall box
5. Insert the wall box into the opening, and attach it to the wall or stud using nails or screws. The front edge should be flush with the outer wall surface. See the following illustration.
CSVEQ 100 D • Installation |