Extron electronic Power supply wiring, CSVEQ 100 D Operation, Power connector wiring

Models: CSVEQ 100 D

1 38
Download 38 pages 17.75 Kb
Page 24
Image 24
Power supply wiring

Operation, cont’d

F

Output equalization (EQ) potentiometer (luma) — Use a

 

small screwdriver to rotate this control to adjust equalization

 

when the line driver is connected to long output cables. The

 

adjustment range is 0 dB to +7 dB. The default is set to 0 dB (the

 

dot position). See "Equalization (EQ) adjustment control" in this

 

chapter.

G

Output gain potentiometer (luma) — Use a small screwdriver

 

to rotate this potentiometer to adjust the luminance gain

 

when the line driver is connected to long output cables. The

 

adjustment range is -1 dB to +3 dB. The default is unity (the dot

 

position). See "Gain adjustment control" in this chapter.

H

Output gain potentiometer (video) — Use a small screwdriver

 

to rotate this control to adjust the gain when the line driver is

 

connected to long output cables. The adjustment range is -1

 

dB to +3 dB. The default is unity (the dot position). See "Gain

 

adjustment control" in this chapter.

I

Output equalization (EQ) potentiometer (video) — Use a

 

small screwdriver to rotate this control to adjust equalization

 

when the line driver is connected to long output cables. The

 

adjustment range is 0 dB to +7 dB. The default is set to 0 dB (the

 

dot position). See "Equalization (EQ) adjustment control" in this

 

chapter.

Power supply wiring

Wire the line driver's power connector as shown below.

Smooth

Ridges

 

A

A

SECTION A–A

3 Power connector wiring3-6 CSVEQ 100 D • Operation5 Manual backgroundManual backgroundManual backgroundManual background

Power Supply

Output Cord

Captive Screw

 

Connector

Power connector wiring

CPower supply voltage polarity is critical. Incorrect voltage polarity can damage the power supply and the line driver. Identify the power cord negative lead by the ridges on the side of the cord.

To verify the polarity before connection, plug in the power supply with no load and check the output with a voltmeter.

3-6 CSVEQ 100 D • Operation

Page 24
Image 24
Extron electronic user manual Power supply wiring, CSVEQ 100 D Operation, Power connector wiring, Operation, cont’d